| International Journal of Current Research and Academic Review |
| ISSN: 2347-3215 Volume 1 Number 4 (2013) pp. 35-41 |
| Experimental study on performance of condenser of two different types used in window air conditioner |
| Madhu Jhariya1* , P.K.Jhinge and R.C. Gupta2 |
| 1 Jabalpur Engineering College, Jabalpur-482011, MP, India 2Department of Mechanical Engineering, Jabalpur Engineering College, Jabalpur-482011, MP, India |
| A B S T R A C T |
| This research paper presents the experimental performance of a window air conditioner with two different types of condensers, single channel and multi channel condenser. The air-conditioner is a 1 TR unit designed for R-22. The performance of the air-conditioner with R-410A is compared with the baseline performance with R-22.The performance parameters considered are cooling capacity, coefficient of performance, energy consumption, and compressor work done. Test results shows that for R-22 the COP of multi channel condenser is 6.6% efficient than the single channel condenser. The cooling capacity of multi channel condenser is 38.4 % higher than the single channel condenser. |
| Keywords |
| Window Air Conditioner; Refrigerant; R-410A; COP; and Cooling Capacity |